CLIA-Waived iCup integrated Urine Drug Screen
Zero Exposure
Combination of 6 commonly tested drugs:
COC. THC, OPI, mAMP, AMP, PCP
Cocaine – COC, Crack, Coke
Marijuana – THC, Hash, Pot, Cannabis, Hashish, Weed
Opiate – OPI
Methamphetamine – mAMP, Meth, Ice, Speed, Crank, Ecstasy
Amphetamine – AMP
Phencyclidine – PCP
Build-in Adulteration Screen
Oxidant – Tests for the presence of acidic and alkaline
Specifiv Gravity – Tests for sample dilution.
PH – Tests for the presence of oxidants, such as bleach and peroxide
CLIA-Waived
iCup with temperature strip
Built-in validity test
Photocopiable Result
Fast Result
FDA cleared for professional use
Result in 5 min
For Home and Office use
ADULTERANT INTERPRETATION
Adulteration is the tampering of a urine specimen with the intention of altering the test results. The use of adulterants can cause false negative results in drug tests by either interfering with the screening test and/or destroying the drugs present in the urine. Dilution may also be employed in an attempt to produce false negative drug test results.
One of the best ways to test for adulteration or dilution is to determine certain urinary characteristics such as pH and specific gravity and to detect the presence of oxidants/PCC, specific gravity, pH
pH: Tests for the presence of acidic and alkaline adulterants. Normal urine pH ranges from 4.0 to 9.0.
Values below pH 4.0 or above pH 9.0 are indicative of adulteration.
Specific Gravity: Tests for sample dilution. Normal levels for specific gravity will range from 1.003-1.030.
Specific gravity levels of less than 1.003 or higher than 1.030 are an indication of adulteration.
Oxidants: Tests for the presence of oxidants, such as bleach and peroxide, in the urine. Oxidants, when
present in the urine, will produce a blue or green color
The 5 panel iCup is a rapid urine screening test that can be performed without the use of an
instrument. The test utilizes monoclonal antibodies to selectively detect elevated levels of specific drugs in urine.
The 5 panel iCup is a lateral flow chromatographic immunoassay for the qualitative
detection of multiple drugs and drug metabolites in urine at the following cut-off concentrations:
Test
Calibrator
Cut-off
Cocaine (COC150)
Benzoylecgonine
150 ng/mL
Methamphetamine (mAMP)
D-Methamphetamine
1,000 ng/mL
Opiate ( OPI 2000)
Morphine
300 ng/mL
Marijuana (THC)
11-nor-Delta9-THC-9 COOH
50 ng/mL
Amphetamine (AMP)
d-Amphetamine
1000 ng/mL
Phencyclidine (PCP)
Phencyclidine
25 ng/mL
Analytical Specificity
The following table lists the concentrations of compounds (ng/mL) that are detected as positive in urine by
the Integrated E-Z Split Key Cup II at 5 minutes.
COCAINE
Benzoylecgonine
300
Cocaine
780
Cocaethylene
12500
Ecgonine
32000
MARIJUANA
11-nor-Delta9 -THC-9 COOH
50
Cannabinol
20000
11-nor-Delta8-THC-9 COOH
30
Delta8 -THC
15000
Delta9 -THC
15000
AMPHETAMINE
d-Amphetamine
300
d,l-Amphetamine
390
l-Amphetamine
50000
3,4-Methylenedioxyamphetamine (MDA)
1560
beta-Phenylethylamine
100000
METHAMPHETAMINE
d-Methamphetamine
1000
p-Hydroxymethamphetamine
30000
l-Methamphetamine
8000
Mephentermine
50000
3,4-Methylenedioxymethamphetamine (MDMA)
2000
OPIATE
Morphine
2000
Codeine
2000
Ethylmorphine
5000
Hydrocodone
12500
Hydromorphone
5000
Levorphanol
75000
6-Monoacetylmorphine (6-MAM)
5000
Morphine 3-Betta-D-glucuronide
2000
Norcodeine
12500
Normorphine
50000
Oxycodone
25000
Oxymorphone
25000
Procaine
150000
Thebaine
100000
PHENCYCLIDINE
Phencyclidine
25
4-Hydroxyphencyclidine
12500